Digital Motion Filter (F6)
Under this function, user can enable digital motion filtering function if the weighing environment is
unstable. User also can engage animal weighing function for maximum performance. The scale is
equipped with 3 filter speeds:
Filt 0 -> Filt 1 -> Filt 2
Transmission Mode (F7)
Under this function, user can select the transmission mode and data format.
First level selection:
StrM / Manu / CMd / Auto
Second level
ForMt
:
SEr.1 / SEr.2
use
ZERO
key to select,
MODE
key to confirm
StrM
: stream mode, data continuous sending when stable (
ForMt
only has
Ser.1
available)
ST, NT,
100.01kg
ST, NT,- 100.01kg
……………………………
.
Manu
: manual mode, data sends once when manually pressing keypad (press
M+
to send one data,
press
MC
to clear memory and send total value)
●
When format is set at
Ser.1
-
Press
M+
to send single data (as
Ser.1
ForMt
), and will not print total value.
ST, NT,
100.01kg
ST, NT,- 100.01kg
……………………………
.
●
When format is set at
Ser.2
-
Press
M+
to send single data, press
MC
to send total value (as
Ser.2
format)
S/N
WEIGHT
UT
1
100.02
kg
←
press
M+
to print single data
2
99.01 kg
3
1210.05
kg
4
10.12 kg
L
…………………………
---------------------------------
Sum
9876.10kg
←
press
MC
to print total value
CMd
: command mode, data sends when receiving command from computer
(READ/ZERO/TARE/NTGS..)
When receiving READ command, indicator will only transmit Ser.1 format.
All other commands will not trigger the data transmission but changing the mode
(ZERO/TARE/NETGS)
NOTE
:
1. When tare function is not engaged, net weight equals to gross weight, so RS-232 will transmit
data in NET status.
Summary of Contents for W75 Series