2. When Command Mode is selected in F7, GROSS status will be transmitted under NTGS command.
ST, NT,
100.01kg
←
net weight
ST, NT,- 100.01kg
US, GS, 1000.01kg
←
gross weight
Auto
: automatic mode, data sends once when weighing result stables
●
When format is set at
Ser.1
-
Indicator will automatically send single weighing result when display stables and over 20e, it does
not support to print total value.
ST, NT, 100.01kg
ST, NT,- 100.01kg
US, GS, 1000.01kg
………………………………
●
When format is set at
Ser.2
-
Indicator will automatically send single weighing result when display stables, press
MC
to clear
memory and print total value (as Ser.2 format)
S/N
WEIGHT
UT
1
100.02 kg
←
automatically send one weighing result when display stables
2
99.01 kg
3
1210.05kg
4
10.12 kg
…………………………
.
----------------------------------
Sum
9876.10kg
←
print total result when
MC
is pressed
●
When Real Time Clock function is enabled
When indicator is set at
rtC.on
, date and time information will be included in the RS-232 data
stream:
When F7 is set at
Ser.1
2015/04/25
10:30:21
ST, NT, 100.01kg
2015/04/25
10:30:39
ST, NT, 210.00kg
When F7 is set at
Ser.2
2015/04/25
10:31:21
S/N
WEIGHT
UT
1
100.02
kg
2
99.01
kg
------------------------------------
Sum
199.03
kg
Printer Selection (F8)
Under this function, user can select the peripheral which the scale will be connected to.
PC
for computer ->
tEC
for Toshiba TEC printer ->
ArGoX
for Argox printer ->
tSC f
or TSC printer ->
SH-24
for 24 columns Dot Matrix printer
Auto Tare & Automatic Continuous Tare (F9)
Summary of Contents for W75 Series
Page 21: ...DISPLAY SEGMENT DEFINITION ...