Check
Is the LOW BATTERY sign on?
Action
Recharge the battery or employed
the AC adaptor.
DATA TRANSMISSION ERROR
Check
Are all transmission parameters
set correctly?
Action
Set all parameters according to
INTERNAL FUNCTIONS.
Check
Is the minimum required weight
obtained/applied?
Action
Refer to Appendix A for minimum
weight requirements?
Check
If both end of the cable linking
scale and computer/printer
firmly secured?
Action
Secure both end firmly.
Check
Is a right data cable used?
Action
Contact your dealer or hardware
engineer.
Check
(For RS232 output ) Is the BASICA
Program file written correctly?
Action
Refer to the operation instruction
and check program file is
correctly written?
Check
Is the BASICA program file (RS232
output only) loaded and run?
Action
Run and load the BASICA program
file.
9.DAILY CARE AND MAINTENANCE
9.1
Avoid exposing scale to direct sunlight or
excess moisture.
9.2
Do not lift/move scale by holding the
platter.
9.3
Do not submerge scale into water.
9.4
Take platter away from scale before
transportation.
9.5
Clean the scale with a soft and damp cloth,
if necessary with a mild detergent.
9.6
Do not use any harsh, abrasive material,
violate solvent thinner or alcohol for
cleaning.
9.7
Verify the accuracy of scale periodically.
Re-calibrate the scale when needed.
NOTE
:In some countries, calibration is
restricted to be done by qualified or
authorized agent only. Contract your dealer
for more information.
9.9
Store scale in a dry and cool place.
Appendix A
Minimum Weight Requirements of Function 11 and
Function 12