![UWE GW -3000 Operation Manual Download Page 12](http://html1.mh-extra.com/html/uwe/gw-3000/gw-3000_operation-manual_1066086012.webp)
information.
7.8.3
Counting Transact ion
Put more subject matter or remove part
of the subject matter, the new piece
value is shown on the display.
7.9
AUTO PIECE WEIGHT ENHANCEMENT FUNCTION
In order to obtain the best counting
result and to avoid sampling error, this
scale is equipped wit h Auto Unit Piece
Weight Enhancement function.
This function is resided in memory once
the unit piece is obtained by the
sampling method as described in 7.8.2.
NOTE:
Auto Unit Piece Weight Enhancement
Function will be terminated if a zero
weight is detected during the
transaction process. It is strongly
piece weight is unknown or individual
piece weight is not standardized.
7.9.1 How Auto Piece Weight Enhancement
Function Works.
7.9.1.1
After a unit piece weight is obtained
by method as described in 7.8.2 then
place more/remove some subject matter
onto the platter. The new quantity will
be shown on the display.
7.9.1.2
The Auto Unit Piece Weight Enhancement
Function will update the unit piece
weight if both of the below requirements
are met:
a. The quantity added to platter is more
than 4 pieces of previous maximum counts
previously attained from the same
transaction.
b. The quantity added to platter is less
than 100% of previous maximum counts
previously attained from the same
transaction.
7.9.1.3
If the above requirements are met, a
new unit piece weight will be displayed
on the Unit Weight window and confirmed
by an audio "beep".
7.10
WEIGHT CHECK FUNCTION
This scale is equipped with Weight Check
Function. An audio and video signal is
generated to reflect the weight check
result.