WARNING
The attention message “Level stop ignored”
is activated if the requested level stop is not
observed. An attention beep* sounds and the
STOP arrow, depth and duration of the ignored
level stop begin flashing.
To complete the dive without shifting to a
lower MB level, you must descend to the
prescribed depth immediately!
MB level
reduced
New MB level
WARNING
The warning “MB level reduced” is activated
if you ascend more than 1.5m/5ft above the
required level stop. The Aladin Sport reduces
the MB level, an attention beep* sounds and
the new MB level is shown in the lower left
corner. To complete the dive without shifting
down to an even lower MB level the new level
stop must be observed.
* Attention beeps can be suppressed. See
chapter:
Settings
, section:
Switching the
sound on and off
.
Total ascent time
Total Ascent Time
(including level stop)
The Aladin Sport displays the level stop
information and the total time of ascent.
This includes the time of ascent as well as
all level stops.
F
NOTE: The total time of ascent
is calculated on the basis of the
prescribed ascent rate. Total time of
ascent can be subject to change if the
ascent rate is not ideal (100%).
Decompression obligation
The Aladin Sport calculates and displays
level stops to reduce microbubble
formation, but it also calculates the diver’s
decompression data.
WARNING
Avoid decompression dives when diving with
MB levels.
Decompression
obligation
How to avoid decompression stops:
• Check ordinary no-stop time by
pressing the right button until L0
appears.
WARNING
At the beginning of a decompression phase an
attention beep sounds and the symbol flashes
for 8 seconds. In order to prevent a dive with
long decompression stops it is recommended
that you ascend a few meters/feet upon
seeing this message.
If decompression stops become obligatory,
the “DECO” symbol will be displayed. The
total ascent time will now also include a
decompression stop.
Level stop and deco stop
When the level stop depth equals the depth
of the first obligatory decompression stop,
and if you are within 1.5m/5ft of the stop
depth itself, the Aladin Sport shows STOP
DECO and STOP (level stop). The indicated
duration refers to the level stop duration.