background image

BioDoc-It

2

 Imaging System 

 

12 

81-0358-01 Rev E

 

 

Post-Processing Tab

 

Auto Rotate:

 Set Auto Rotate to 

ON 

to automatically rotate the image to the desired degree upon 

image capture. 

Note: “Auto Rotate” must be set to 

ON 

in order to rotate images during image capture, 

as images cannot be rotated after capture using the 

VisionWorks 

touch. 

 
To select the degree of image rotation, press the down arrow from the drop-down menu and choose to 
rotate the image 90 degrees clockwise, 90 degrees counterclockwise, or 180 degrees (upside down). 

Note: “Auto Rotate” must first be turned 

ON 

before selecting a rotation setting. 

 

Auto Invert Image:

 Set Auto Invert Image to 

ON

 to automatically invert the image upon image capture. 

Note: “Auto Invert Image” must be set to 

ON 

in order to invert images during image capture; captured 

images can also be inverted in the Gallery view.

 

 

Noise Subtraction:

 Set Noise Subtraction to 

ON

 to reduce the amount of background and ambient 

(“white”) noise within the image. In most circumstances, this setting should be left 

ON

Note: “Noise 

Subtraction” must be set to 

ON 

in order to subtract noise from images during image capture, as noise 

cannot be subtracted from images after capture using the 

VisionWorks 

touch.

 

 

Saving Tab

 

Save Format:

 Press the down arrow to select the desired file save format from the drop-down menu. 

Save images in 

JPEG

TIFF

BMP

 or 

PNG

 file formats.  

 
From the drop-down menu to the right of the chosen file format, choose 

Save Selected Format 

to save 

the image only in the chosen format. Or, select 

Save Selected & Original Formats 

to save in both the 

selected format as well as in an uncompressed TIFF format (note: two separate files will be saved using 
this method). 
 

Note: If the TIFF file format is selected and 

Save Selected & Original Formats 

is also selected, both 

compressed and uncompressed TIFF files will be saved.  

 

Save Images To:

 Select the location where images are to be saved. The black dot within the radio 

button indicates which selection is activated.  
 
1.  Select 

USB

 to save the file to the USB drive if one is currently inserted. If a USB device is not 

present, the user will be notified that a USB drive is not present when attempting to save an image.  
 

2.  Select 

Prompt for Location

 to prompt the user to select a file save location when attempting to 

save an image. This setting will also allow the user to save using a custom file name. 
 

3. 

Choose 

Select Folder

 to define where the file will be saved when attempting to save an image. 

Select from any local or network drive by pressing the folder icon to the right of the file path display. 

Note: The 

Select Folder 

radio icon must first be selected prior to defining the save location. 

 

Auto Save After Capture:

 Set 

Auto Save After Capture

 to 

ON 

to automatically save the image after 

capture. The image will automatically save to the location selected in 

Save Images To 

and in the format 

selected in 

Save Format

,

 

as described

 

above. 

 
NOTE:

 If the 

Auto Save After Capture

 function is set to 

OFF

, press the 

Save

 button in the Gallery view 

to manually save an image.  

 

Auto Print After Capture:

 Select 

ON 

to automatically send the captured image to the default printer 

after an image is captured. 

If a default printer is not installed, the Windows “Printers and Faxes” dialog 

will automatically appear 

after the image is captured. Select the desired printer in the “Printers and 

F

axes” dialog box and press 

OK

 on the dialog box to print the image. 

 

Accept or Cancel Settings

 

Once all Preferences settings have been made, press the 

Checkmark

 button at 

the bottom of the Preferences screen to save all preferences and go back to the 

Summary of Contents for biodoc-it 2

Page 1: ...nd User Instructions UVP LLC Ultra Violet Products Ltd 2066 W 11th Street Unit 1 Trinity Hall Farm Estate Upland CA 91786 Nuffield Road Cambridge CB4 1TG UK Phone 800 452 6788 Phone 44 0 1223 420022 F...

Page 2: ...the UVP factory 7 Note The zoom lens shipped may appear different than pictured 7 Using the System 8 Powering Up the Tablet 9 Operating the VisionWorks touch Interface 9 Using the Transilluminator 9...

Page 3: ...C or Mac programs The BioDoc It2 Imaging System is a cost effective solution for capturing quality images in a compact standalone package as no external computer is required The BioDoc It2 comes stand...

Page 4: ...specific parts and components included with the system 10 Integrated Touch Screen White Light and UV Power Buttons Wide Access Door USB Port Not Shown Two Position Filter Tray Including EtBr Filter T...

Page 5: ...315 uses a USB 2 0 connection All camera settings are factory pre set for optimum performance when viewing gels and films under low light level conditions Contact UVP Technical Support before making a...

Page 6: ...e the Touch Screen Interface section in this manual Fluorescent Focus Target The UVP Fluorescent Focus Target fluoresces when placed on a UV transilluminator or when exposed to overhead UV The Target...

Page 7: ...o a surge protected power outlet 2 Connect the jumper cable from the darkroom to the rear of the transilluminator Installing Emission Filters To install the 50mm2 ethidium bromide EtBr filter and any...

Page 8: ...f the lens and the rubber gasket beneath the darkroom bracket 4 Plug the camera cable into the top of the camera and the other end into a USB port on back of the darkroom Camera and lens assembly Came...

Page 9: ...interface press either the close X or minimize _ buttons at the top right corner of the software window Refer to Touch Screen Interface in this manual for further instructions on using the software U...

Page 10: ...ive film from the Fluorescent Focus Target see the Fluorescent Focus Target section of this manual for more information 2 Turn on the transilluminator and place the Target on the transilluminator surf...

Page 11: ...n in the upper right corner of the main TS screen and selecting from the following tabs General Settings Post Processing Saving The following pop up screen will appear General Settings Tab Language Us...

Page 12: ...e TIFF file format is selected and Save Selected Original Formats is also selected both compressed and uncompressed TIFF files will be saved Save Images To Select the location where images are to be s...

Page 13: ...interface language and image save format See the Setting User Preferences section of this manual for further information Templates Press the Templates button to access the list of templates Press aga...

Page 14: ...s to select modes for image capture Use the vertical slider bars and or the and buttons to make adjustments to the desired portion of the exposure time sec ms or microseconds To adjust capture modes s...

Page 15: ...exposed image decrease the aperture or exposure time until the yellow or red overlay disappears To activate saturation warning press the Saturation Warning slider until the check mark appears Action P...

Page 16: ...e Minimize button to close full screen mode Close Press the Close button to the right of the image to close the active image If the image is unsaved the user will be prompted to save the image before...

Page 17: ...l the check mark appears This will add mmm dd yyyy hh mm ss to the bottom right corner of the image NOTE The time stamp is not saved to the image unless Save Burned is selected as described earlier in...

Page 18: ...ving 3 To access saved templates press the Templates button as shown 4 To select the quick access templates to be shown at the top of the TS screen press the Templates button until the list of saved t...

Page 19: ...for network configuration To minimize the VisionWorks touch interface and access Microsoft Windows for network configuration press the Minimize _ button in the upper right corner of the software Inst...

Page 20: ...de 50mm Square 38 0220 01 Filter SYBR Green 50mm Square 38 0219 01 Filter SYBR Gold 50mm Square 38 0221 01 Transillumination Accessories White Light Converter Plate 21x26cm 38 0191 01 White Light Conv...

Page 21: ...the Screen 1 An error message that is related to the VisionWorks touch interface or Microsoft Windows may appear on the screen If the message is related to Microsoft Windows such as a reminder to acti...

Page 22: ...ffices at the locations below or visit www uvp com If you are in North America South America East Asia or Australia If you are in Europe Africa the Middle East of Western Asia Call 800 452 6788 or 909...

Reviews: