Setting Type
Global
Command TESTPAT
state
Parameters
state
Return Values
Range
ON TP0
Enable test pattern TP0
ON TP1
Enable test pattern TP1
ON TP2
Enable test pattern TP2
ON TP3
Enable test pattern TP3
OFF
Disable test pattern
Type string
Example
TESTPAT ON TP0
TESTPAT ON (Defaults to TP0)
TESTPAT TP2 (ON is default)
TESTPAT OFF
5.18.2.
Get Test Pattern State
Description
Returns the state of the test pattern.
Setting Type
Global
Command TESTPAT?
Parameters none
Return Values
state
Range
ON
Test pattern enabled
OFF
Test pattern disabled
Type string
Example
TESTPAT? -- query command
ON TP3 -- return value
5.18.3.
Set Frame Stamp
Description
Sets the frame stamp state. When ON, a count value incrementing
by 1 of extents 0 to 4095 is returned in place of the first pixel in the
frame.
Setting Type
Global
Command FRAME:STAMP
state