![UTS AEROSPACE SYSTEMS SU640CSX Operation Manual Download Page 77](http://html1.mh-extra.com/html/uts-aerospace-systems/su640csx/su640csx_operation-manual_1065633077.webp)
SU640CSX
4110-0462, Rev. B
Page 77 of 97
© 2016 UTC Aerospace Systems
Date Printed: 1-Dec-2016
This document does not contain any export controlled technical data.
5.16.18.
Set Power-Down Detect Flag
Description
Sets the power-down detect flag to 1. On reboot, this flag is
initialized to 0. As the value is set using this command, the user can
query its status to detect if the camera has been power cycled since
the last query. The command sets the flag; only a reboot will reset
the flag to 0.
Setting Type
N/A
Command PWRDWN
Parameters none
Return Values
none
Range N/A
Type N/A
Example
PWRDWN -- set power-down detect flag
5.16.19.
Get Power-Down Detect Flag
Description
Returns the power-down detect flag status.
Setting Type
N/A
Command PWRDWN?
Parameters none
Return Values
value
Range
0
Initial value on reboot
1
Value set by user to monitor power-down status
Type unsigned
integer
Example
PWRDWN? -- query command
1 -- camera not power cycled
5.16.20.
Set LED State
Description
Sets the state of the status LED. Note: At least one SUI camera used
the command LED instead of as shown. If you have legacy software
code and are experiencing difficulty, check the command being
used.
Setting Type
Global
Command LED:ENABLE