![UTS AEROSPACE SYSTEMS SU640CSX Operation Manual Download Page 54](http://html1.mh-extra.com/html/uts-aerospace-systems/su640csx/su640csx_operation-manual_1065633054.webp)
SU640CSX
4110-0462, Rev. B
Page 54 of 97
© 2016 UTC Aerospace Systems
Date Printed: 1-Dec-2016
This document does not contain any export controlled technical data.
Range
0 to 5
Type unsigned
integer
Example
ENH:AVG? -- query command
0 -- response
5.9.7.
Set Enhancement Power Function
Description
Sets the power function value for manual enhancement mode. This
function only affects data when in manual enhancement mode
(ENH:AUTO OFF) with enhancements turned on (ENH:ENABLE
ON). See Section 0 for a full description.
Setting Type
Global
Command ENH:POWER
value
Parameters
value
Return Values
none
Range
0 to 10
Type unsigned
decimal
Example ENH:POWER
0.6
5.9.8.
Get Enhancement Power Function
Description
Gets the power function value for manual enhancement mode.
Setting Type
Global
Command ENH:POWER?
Parameters none
Return Values
value
Range
0 to 10
Type unsigned
decimal
Example
ENH:POWER?
-- query command
0.6
--
return
value
5.10.
Pixel Clock Commands
The camera electronics are designed to support a variety of focal plane arrays with varying requirements
for pixel clock rate. The pixel clock is operated for the supported focal plane array at the maximum pixel
clock rate reported through the command interface. The pixel clock period is needed to calculate exposure