Range N/A
Type string
Example
HELP? OPR -- query command
Sets the camera OPR -- response: text description of the query.
5.16.16.
Status and Reset Commands
The user can poll the camera’s error status with the error command, which returns a binary encoded 32-bit
error value. A non-zero error code indicates that an error has occurred. Table 8 below can be used to
decode the error value returned by the error command. A bit value of one indicates an error. Use the
“ON” argument
Bit
Error
Description
Cause Resolution
0 (LSB) PLL0 error
Internal error
Power cycle camera
1
PLL1 error
Internal error
Power cycle camera
2
PLL2 error
Internal error
Power cycle camera
3
Expose Block
Error
Invalid exposure and /
or frame rate timing
1. Increase readout time by modifying
exposure and frame periods.
2. Reduce trigger rate.
3. Reset firmware, reboot camera, or send a
trigger command that causes a trigger
parameter change (see Section 5.12.)
4
Data RX PLL
Lock Error
Internal error
Power cycle camera
5..15 Unused
Unused
Unused
16 I2C0
Error
Internal
Error
Power cycle camera
17
I2C1 Error
Internal Error
Power cycle camera
18 I2C2
Error
Internal
Error
Power cycle camera
19 I2C3
Error
Internal
Error
Power cycle camera
20
System
Temperature
Alarm
Camera Temperature
is out of acceptable
range
1.
Reduce camera case temperature.
2.
Disable TEC.
3.