50 / 69
Returned content: 193 (basic paserial paserial parameter)
4. Return results of save settings command
If settings are correct, it returns:
FF 01 04 4B
5. Return results of basic settings command
FF 01 05 4B
6. Others return results
Sum check fault returns 'E' + right parity
Correct execution: FF 01 CMD 'K'
User name/password fault returns: FF 01 CMD 'P'
Others faults return: FF 01 CMD 'E'
4.2. Serial Setting Protocol
4.2.1. AT Command
AT Command List:
Table 1 AT Command List
Command
Instruction
(blank)
Blank Command
E
Open/close echo function
Z
Re-start device
VER
Query version number
ENTM
Enter to transparent transmission mode
MAC
Query/set MAC
UART
Set/query serial port parameter
SOCKMN
Set SOCK parameter
DHCPEN
Open/close automatic obtaining IP address
WANN
Open/close WAN port parameter
WEBU
Query/set web page user’s name and password
WEBPOR
T
Query/set web page port number
SEARCH
Query/set searching key words
CLEAR
Factory reset
UART
Set/query serial port 0 parameter
Summary of Contents for USR-N520
Page 1: ...1 69 User Manual File Version V1 0 4 ...
Page 17: ...17 69 UDP Client Software Configuration UDP Client Testing Screenshot ...
Page 27: ...27 69 2 Set modbus slave software refer to the following ...
Page 28: ...28 69 3 Return result for query command is as drawing ...
Page 33: ...33 69 Drawing 26 Self Defined Heartbeat Function ...
Page 35: ...35 69 2 Testing result ...
Page 37: ...37 69 Web to Serial COM Send Receive Data ...
Page 40: ...40 69 2 Set Printer Driver ...
Page 59: ...59 69 Software Configuration Full Show ...
Page 69: ...69 69 ...