3.5.11. KeepAlive
When USR-N520’s network is abnormal, it can judge the status in time and disconnect. And connect to
server once network recovers.
3.5.12. Device ID
The function have 2 types: send ID once connection and send ID once sending data. It is used to
condition that need register packet or need packet header/tail for normal transmission.
3.5.13. Webpage Port
USR-N520 has built-in webpage server and the port is 80. Also the port can be revised and visit the web
via revised port.
3.5.14. Revise MAC
User can check software’s MAC address. USR-N520 MAC is Globally Unique. Also it support customized
MAC.
3.5.15. Firmware Upgrade
Firmware upgrade is fulfilled via network. For details, please refer to Chapter 5.1 configure parameter with
configuration software.
3.5.16. Hardware Flow Control RTS/CTS & XON/XoFF
RTS/CTS: USR-N520 supports serial RTS/CTS Hardware flow control function. It is disabled by default.
Don’t enable it if device doesn't support Hardware flow control . This function is only run under RS232 port.
XoN/XoFF: USR-N520 support software flow control function. It is disabled by default. It can be selected
under RS232 port or RS422 port.
3.5.17. Reload
Cut off power firstly.
Press “reload” and supply power. Then keep pressing reload for 5 seconds.
Summary of Contents for USR-N520
Page 1: ...1 69 User Manual File Version V1 0 4 ...
Page 17: ...17 69 UDP Client Software Configuration UDP Client Testing Screenshot ...
Page 27: ...27 69 2 Set modbus slave software refer to the following ...
Page 28: ...28 69 3 Return result for query command is as drawing ...
Page 33: ...33 69 Drawing 26 Self Defined Heartbeat Function ...
Page 35: ...35 69 2 Testing result ...
Page 37: ...37 69 Web to Serial COM Send Receive Data ...
Page 40: ...40 69 2 Set Printer Driver ...
Page 59: ...59 69 Software Configuration Full Show ...
Page 69: ...69 69 ...