43 / 69
Synchronous baud rate is named RFC2217. USR Similar RFC2217 make adjustments on the basis of
RFC2217 protocol to improve accuracy of transmission.
Protocol length is 8 bytes. And values taken for example is in HEX:
Name
Packet
Header
Baud Rate
Bytes parameter
Parity
Bytes
3
3
1
1
Explanation
reduce
misjudgment
High is in front,
smallest is
600(00 02 58)
data bytes, baud
rate, parity
Remove 4 bits
of header and
ignore the high
bit
(115200,
N,8,1)
55 AA 55
01 C2 00
03
46
(9600,
N,8,1)
55 AA 55
00 25 80
03
28
Serial parameter bit:
Bit #
Explanation
Value
Description
1:0
Data bit selection
00
5 bits
01
6 bits
10
7 bits
11
8bits
2
Stop Bit
00
1 bit
01
2bits
3
Parity Enable
00
Disable Parity
01
Enable Parity
5:4
Parity Type
00
ODD
01
EVEN
10
Mark
11
Clear
8:6
NC
000
0
Using methods:
1. USR-TCP232-M4,E45 Setup software, click “Synchronous baud rate (RFC2217)”.
2. When serial parameter changes is needed, it send RFC 2217 packet. USR-N520 receive the
command from network and revise serial parameter accordingly.
Summary of Contents for USR-N520
Page 1: ...1 69 User Manual File Version V1 0 4 ...
Page 17: ...17 69 UDP Client Software Configuration UDP Client Testing Screenshot ...
Page 27: ...27 69 2 Set modbus slave software refer to the following ...
Page 28: ...28 69 3 Return result for query command is as drawing ...
Page 33: ...33 69 Drawing 26 Self Defined Heartbeat Function ...
Page 35: ...35 69 2 Testing result ...
Page 37: ...37 69 Web to Serial COM Send Receive Data ...
Page 40: ...40 69 2 Set Printer Driver ...
Page 59: ...59 69 Software Configuration Full Show ...
Page 69: ...69 69 ...