48 / 69
2
Port settings parameter command
Port parameter:
Name
bytes
example
Explanation
ulBaudRate
4
00 C2 01 00
Baud Rate
ucDataSize
1
08
COM data bits (0X05/0x06/0x07/0x08)
ucParity
1
01
COM parity
1: no, 2: odd, 3: even, 4: mark, 5: space
ucStopBits
1
01
COM stop bit (0x01/0x02)
ucFlowControl
1
01
COM flow control ( 0x01; no, 0x03:HW)
ulTelnetTimeout
4
00 00 00 00
Network reconnection time
usTelnetLocalPort
2
17 00
Local Port
usTelnetRemotePort
2
17 00
Remote Port
uiTelnetURL
30
31 39 32 2E 31 36 38
2E 30 2E 31 00 00 00
00 00 00 00 00 00 00
00 00 00 00 00 00 00
00 00
IP address send in ASCII.
Example: 192.168.0.1
ulTelnetIPAddr
4
00 00 00 00
Not adopted
ucFlags
1
02
Enable MODBUSTCP
:
0x010(bit2)
Enable 2217: 0x08(bit3)
Enable USR cloud: 0x010(bit4)
ucWorkMode
1
03
Working mode:
0: UDP, 1: TCP Client, 2: UDP Server,
3: TCP Server, 4: HTTPD Client
uiPackLen
4
C8 00 00 00
COM pack length
ucPackTime
1
0A
COM pack time
ucTimeCount
1
91
Write the read values
TCP server type
1
1
Write the read values
ucReserved
4
Casual value
saved
Example:
FF 52 06 AC CF 23 66 66 67 61 64 6D 69 6E 00 61 64 6D 69 6E 00 00 C2 01 00 08 01 01 01 00 00 00 00
17 00 17 00 31 39 32 2E 31 36 38 2E 30 2E 32 30 31 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 08 03 C8 00 00 00 0A 95 11 00 00 00 00 42
Summary of Contents for USR-N520
Page 1: ...1 69 User Manual File Version V1 0 4 ...
Page 17: ...17 69 UDP Client Software Configuration UDP Client Testing Screenshot ...
Page 27: ...27 69 2 Set modbus slave software refer to the following ...
Page 28: ...28 69 3 Return result for query command is as drawing ...
Page 33: ...33 69 Drawing 26 Self Defined Heartbeat Function ...
Page 35: ...35 69 2 Testing result ...
Page 37: ...37 69 Web to Serial COM Send Receive Data ...
Page 40: ...40 69 2 Set Printer Driver ...
Page 59: ...59 69 Software Configuration Full Show ...
Page 69: ...69 69 ...