41
ISS Sensor Signal Plausibility Error
The controller detected an unexpected value from this sensor and marked it as
faulty. (if equipped)
Checksum error in table (Can be table 1-4)
A Checksum error has been found in the table corresponding to the number
shown. On Quick 6, this error will force a hard failsafe mode until it is fixed. It will
also disable the tuning menu for the bad table. Connect the controller to a PC
and load a calibration using Shiftware.
Torque Converter Clutch Slip Error
Torque converter clutch slip detected when fully engaged.
Transmission Slip in Gear(s) 1, 2, 3, etc.
Transmission appears to be slipping in the indicated gear or gears.
Transmission Slip with Max Pressure
Transmission continued to slip after maximum line pressure was commanded.
Transmission Slip Repeated > 2x
Transmission slip was detected more than twice in this drive cycle (max. line
pressure latched).
Ratio too High in Gear(s) 2, 3, 4, etc.
Transmission gear ratio appears to be too high in the indicated gear or gears.
Error: PRNDL Out of Range
Sensor voltage is out of tolerance limits, but within approximate range.
Error: PRNDL Signal Low
Sensor voltage is low.
Error: PRNDL Signal High
Sensor voltage is high.
Error: No PRNDL PWM Signal
Connect the controller to a PC and use Shiftware to reload the calibration using
a E4OD calibration.
Summary of Contents for Quick4 4R100
Page 1: ...Installation and Operation Manual for E4OD and 4R100 Transmissions ...
Page 7: ...7 ...
Page 13: ...13 TRANSMISSION DIAGRAMS ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 22: ...22 ...
Page 30: ...30 Home Screen Normal Mode Home Screen Enlarged Mode ...
Page 43: ...43 ...