60
DS1083-046A
8.3.5.
The page shown here by the side will appear if SECONDARY calling module
type is selected.
Set the column number of the secondary module on the keypad and press
OK
to con
fi
rm the selection.
Permitted values: 0 ÷ 31
No speci
fi
c error is indicated if an incorrect column number is set
but no user can be called.
8.3.6.
Each column may have up to two secondary modules. Set the identi
fi
cation
code (ID) of the secondary module in the riser on the keypad and press
OK
to
con
fi
rm the selection.
Permitted values: 0 or 1.
Secondary module ID errors will only be shown when exiting
con
fi
guration mode and returning the device to normal operating
mode.
8.3.7.
Select the user CODE TYPE used with the
buttons and press
OK
to
con
fi
rm.
See the
Parameter table
for more information on PHYSYCAL and LOGICAL
mode.
8.3.8.
The AUTOMATIC FIT function automatically replaces physical codes with
sequential logical codes from 1 to 127 according to the following pattern:
Physical code
Logical code
1
1,
fi
rst logical address used
1
2, second logical address used
÷
÷
1
127, last logical address used
IMPORTANT:
This function is only available if:
The addressing method of the system uses logical codes.
The calling module is a secondary module or the primary calling module in
a one-riser system.
Select the function activation module type with the
buttons and press
OK
to con
fi
rm.
The automatically allocated logical codes can be modi
fi
ed at any
time and logical code 128 can be allocated to physical code XY000
(if there are 128 users in the system or on the riser), where XY is
the riser number (00 for single riser systems).
1.
2.