3. If you have punched out for a break and need to punch in again, press the IN button
that corresponds with the third column, and insert the time card. The punch will print in
the third column.
4. You can press the next OUT button to punch out for another break or at the end of a
shift. The six columns on the time card allow for you to punch in and out three times
each, per day.
HN SERIES AUTO-ALIGN ERROR CODES
If an error occurs, your time clock will display the following error code.
ER 01—
Wrong side of time card inserted.
ER 21—
Battery needs to be charged.
ER 91—
Print Head Motor Issue: wrong position, left and right.
ER 92—
Card Feed Motor Issue: wrong position, up and down.
RESETTING THE HN SERIES AUTO-ALIGN TIME CLOCK
To simply restart the time clock, press the
Reset
button.
To restore the default values, move the
Set
switch to the “0” position (to the right). Then
press the
+
,
Clear
, and
Mode
keys simultaneously until you hear three beeps. Finally, move
the
Set
switch back to the “
–
” position (to the left). Setting the clock to factory reset will
restore the default values, including: Date, Time, Time Signal, Print Color Options, and
Printing Position.