Interface Bracket Installation

Before beginning the installation:
1.  Select the mounting location of the interface.  

The interface on a wall or on the cover of the  
base unit.

2. Obtain installation report.
3. See wiring diagram in 

Section 12

.

4. Disconnect the power to the base unit.
5. Open the base unit cover.

Interface Bracket Wall Mounting

Mount the bracket at approximately 
eye level.

1.  Hold bracket to wall; mark 

mounting-hole locations on the  
wall with a pencil.

2. Drill the wall.
3.  Press the anchor into the hole.
4.  Attach the interface brackets to the 

wall with screws.

Interface Bracket Mounting  
on the Base Unit

1.  Fix screws on the bracket cover. 

(Use cover marking as a guide.) 

2.  Let the screws protrude slightly  

from the base unit.

2. Hang the bracket on the screws.

Wiring and Programming the Interface

Do not remove the yellow data stick from the interface 
before powering up and setting the language.

Wiring the Interface

If the interface is located less than 6 feet from the 
controller, use the cable (interface to base unit) fitted 
with RJ 9 connectors at each end.

1. Connect the RJ 9 connector into the base unit #1.
2. Secure the cable in the clamp.
3.  Connect the RJ 9 connector in the back of  

 the interface.

4. Secure the cable in the cable guide.

If the interface is located more than 6 feet away from the 
controller, use the installation cable.

Wiring is polarized. Connect terminal 1 on the 
base unit to terminal 1 on the interface, etc.

Base Unit

1.  Without turning, press with a small screwdriver on the 

button of the terminal to insert or remove a wire.

2. Insert a wire in the quick connector.
3. Remove the screwdriver.
4. Secure the cable in the clamp.

Interface I-75

5.  Without turning, press with a small screwdriver on the 

button of the terminal to  insert or remove a wire.

6. Insert in the quick connector on terminal.
7.  Remove the screwdriver.  

Release quick connector button.

8. Secure the cable in the cable guide.

Maximum cable length: 60 feet

5 feet

Summary of Contents for C-55

Page 1: ...Climate Co ntrol Zoning System Installation Guide RADIANT HEATING AND COOLING SYSTEMS CLIMATE CO NTROL ZONING SYSTEM INSTALLATION GUIDE...

Page 2: ...stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Page 3: ...Unit Installation 5 Base Unit Diagram 5 Preparation Before Installation 5 Components Installation 6 Section 4 Thermostat Installation 11 Label the Room Thermostats 11 Register Room Thermostats 12 Det...

Page 4: ...witched off when wiring Uponor is not responsible for damages and breakdowns that may result from not following the instructions in this guide Symbols Used in This Manual Warning Risk of bodily injuri...

Page 5: ...75 The thermostat displays the temperature on its screen The thermostat is affected by the temperature of surrounding surfaces as well as the ambient air temperature A thermostat calls for heat by se...

Page 6: ...r the connection of the base unit Protect the mounting locations for the Zoning System from moisture Use one thermostat for every zone with radiant floor heating Base Unit C 55 Base Unit C 55 Antenna...

Page 7: ...e 2 Connect the RJ 9 connector into the antenna 3 Clip the antenna into the base unit 4 Insert the cable of the antenna into the hole of the base unit Connect to terminals 9 and 10 Fastening the Anten...

Page 8: ...11 and 12 Warning Disconnect the power before installing or changing the device wiring Powering the Base Unit Check the actuators and antenna to ensure that the wiring is complete Check that the powe...

Page 9: ...e Thermostat Display T 75 Label the Room Thermostats Install two alkaline AAA 1 5V batteries in each thermostat see page 26 Label the thermostats with the channel numbers they are to control e g 02 03...

Page 10: ...The LED of the cancelled channel flashes for two seconds then switches off 3 Press the Test button to exit registration mode The Test LED switches off Caution To register a different thermostat to a...

Page 11: ...s for the channels registered to the thermostat stay on Note See Section 11 Troubleshooting for guidance 3 To exit the Test mode press the Test button To verify functionality increase setpoint of the...

Page 12: ...that the antenna is correctly mounted Check if the thermostats are powered 2 Close the cover of the base unit Close the thermostat covers where necessary 3 Complete the installation report Section 12...

Page 13: ...w data stick from the interface before powering up and setting the language Wiring the Interface If the interface is located less than 6 feet from the controller use the cable interface to base unit f...

Page 14: ...1 is the controller connected to the interface Connect terminal 5 and 6 of base unit 2 to terminal 5 and 6 of base unit 1 Connect terminal 7 and 8 of base unit 3 to terminal 7 and 8 of base unit 1 or...

Page 15: ...or Increases the value Moves to line below or Decreases the value Press OK Displays the next screen or Confirms selection and displays the screen of the current menu 1 Uponor screen Main Menu Settings...

Page 16: ...eat Demand Management 2 Choose Common or Individual Press OK A common pump relay must not be connected to more than one base unit Setting the Exercise Setup Schedule a weekly five minute activation to...

Page 17: ...ns Displays the next menu or Goes to next field Displays the previous menu or Goes to previous field Goes to line above or Increases the value Goes to line below or Decreases the value Press OK Displa...

Page 18: ...lem is reported Alarms System Rooms Information 1 07 Gym 1 02 Living Room List Battery 1 02 Living More Signal Measured Set Point 1 02 Living More 69 8 F 70 16 F StatCall No Act Closed 1 02 Living Mor...

Page 19: ...ngs Menu The settings menu allows the user to set the base unit for individual rooms The number at the beginning of the room name on the display means First digit base unit number 1 2 3 second and thi...

Page 20: ...e 2 Press OK Exercise Valve and Pump 1 Uponor screen Main Menu Settings System Parameters Valve Pump Exercise Exercise Valve and Pump 2 Set the time and date for the five minute activation Press OK Ex...

Page 21: ...nection Diagram Connection of the interface with the cable fitted with RJ 9 connectors 6 foot cable Terminal block for connection of antenna and extensions for additional I 75 interface Interface RJ 9...

Page 22: ...oller cover The LED of the channel from which the alarm originated is blinking rapidly See Section 11 Troubleshooting Automatic Exercise Function The system is fitted with an automatic exercise functi...

Page 23: ...indicates an alarm or error message To resolve 1 Remove the base unit cover to see power LED 2 If LED is blinking there is an error 3 Verify which thermostat is creating the alarm If an interface is f...

Page 24: ...orrectly Base Unit and Antenna Poor radio reception Antenna mounted inside metal cabinet Antenna out of position or wire disconnected Interference Change the location of the antenna Power LED and chan...

Page 25: ...t Room temperature OK but the floor is cold Supply system defect no warm water in manifold Check boiler and circulation pump All rooms are cold Vacation mode still on End vacation mode ECO mode Change...

Page 26: ...nd or antenna to prevent interference Base Unit Interface or Actuator Short circuit alarm on interface Power LED and concerned channel LED blink Short circuit on a connected actuator Check wiring of t...

Page 27: ..._____________________________________________ Company Name_________________________________________________________________________________ Address_____________________________________________________...

Page 28: ...ww uponor usa com www uponor ca 48 Uponor Climate Co ntrol Zoning System Installation Guide 49 Option Option Base Unit Number Channels Rooms 2 Pump Yes No Base Unit Number Channels Rooms 3 Pump Yes No...

Page 29: ...www uponor usa com www uponor ca 50 Uponor Climate Co ntrol Zoning System Installation Guide 51 Notes...

Page 30: ...www uponor usa com www uponor ca 52 Uponor Climate Co ntrol Zoning System Installation Guide 53 Notes...

Page 31: ...MN 55124 USA Tel 800 321 4739 Fax 952 891 2008 Web www uponor usa com Uponor Ltd 655 Park Street Regina SK S4N 5N1 CANADA Tel 888 994 7726 Fax 800 638 9517 Web www uponor ca CC Zoning_InsG_5 08 Copyr...

Reviews: