3.
Setting and Unsetting
CommPact User Manual
11
Setting with the Keyfob
The default functions for B1 is part setting and for B2 -- perimeter setting.
To set the system using the keyfob:
•
Press the relevant button/buttons on your keyfob (see below); the exit
delay begins to count down. At the end of the exit delay, the system is
set.
Combination setting
There is an option to activate two setting modes simultaneously.
The possible combinations are:
•
Full + perimeter
•
Part + Perimeter
For combination setting, activate the first setting mode, and, while the exit delay of the
first setting mode is counting down, activate the second setting mode. It is not important
which setting mode you choose first.
It is not possible to activate Full and Part setting modes simultaneously.
It is necessary to unset first when changing from one setting mode to another
setting mode.
Forced Setting
Forced setting enables you to set when the system is not ready. For example, if a door
protected by a magnetic contact is open, you may set the system on condition that the
door will be closed by the end of the Exit delay. If the door is still open after the exit
delay expires, an alarm is generated.
Forced setting is available only if the option is enabled in programming.
Instant Setting
Instant setting is a feature that allows you to cancel the entry delay after Part or
Perimeter setting the system. For this feature to function, it must be enabled in
programming by your engineer.
To instantly set the system.
1.
Check if the system is ready to set.
2.
Press the Part or Perimeter setting button on the keypad (enter your user
code if required).
3.
Press and hold down
on your keypad until the message
Instant Setting, OK?
is
displayed
4.
Press
; the entry delay for the current setting period is canceled.