ÜKYP/YP Automatic Fuel Loading, Central System Heating Boiler Usage and Maintenance Manual 

  Gearbox On/Off and 

Manual Fuel Feed

 Fuel Feed and 

Fuel Wait will not work. 

The boiler does not operate because the

 Gearbox On/Off and

 

Fan On/Off buttons are not pressed in the adjacent display. 
It is useful to adjust the boiler water temperature to 60

o

C at the first start-up. For 

this, first press the 

Temperature Setting button on the panel. 

TEMPERATURE SET will appear on the screen. You can press and hold 

the buttons until you reach the temperature you want to set. 

When it reaches the desired level, you can memorize it by pressing the 
ENTER button. 

 

Press the 

Fan Setting button of the panel. A rectangle will appear around 

the line in the upper left corner. 
 

 When you press the button once, it increases the fan level once more and 

as in the second figure, 

As soon as you press the 

ENTER button, the fan setting you have set will be 

memorized and the image on the screen will be as in the third figure. 

 
 
 
 
 

Ignite the auxiliary materials you put in the boiler. 

Then close the boiler covers tightly and press the

 Fan On/Off button on 

the panel. The Fan lamp on the top right of the control panel will turn on and the 
boiler will continue to heat. 

 

Pressing the

 ON/OFF button will be sufficient to turn off the boiler. As long as the power is not 

disconnected (power failure, unplugging the boiler), the pump will continue to run until the temperature 
drops. 

 

Increasing the fan speed more than necessary will cause some heat to be discharged 
from the chimney. Air given suddenly and in large quantities during combustion will 
cause sticking in the slags. 
 

 

 

Boiler covers and hopper cover should not be left open during combustion. 

 

 

 

In the first start-up, the ignition may fail because the flue temperature will heat up late 

and the fuel loading auger is empty. Let it ignite again by turning it off and on. 

Summary of Contents for UKYP/YP 130

Page 1: ...LET FIRING CENTRAL HEATING BOILER USER MANUAL NL SOY Yap Malzemeleri Sanayi ve Ticaret Ltd ti Pancar Organize Sanayi B lgesi 2 Etap No 2 Torbal IZMIR TURKEY Tel 90 444 35 32 Fax 90 232 469 2412 www un...

Page 2: ...SITE 4 SAFETY WARNINGS 6 ELECTRICAL INSTALLATION INSTRUCTIONS 8 INFORMATION ABOUT COMBUSTION 10 BOILER FEATURES 12 RULES FOR HEATING INSTALLATION 14 CONTROL PANEL AND USER INTERFACE 18 START UP 20 FUE...

Page 3: ...omestic hot water with the help of a boiler or heat exchanger The energy required for the domestic water will be taken from the boiler energy KYP YP heating boilers convert the chemical energy of the...

Page 4: ...tands on its chassis care should be taken that the carrying rope does not damage the painted thin sheets of the boiler and the reducer fan group under the bunker It is convenient to lift the boiler fr...

Page 5: ...ble solution The boiler room door must not open directly to the escape staircase or general use stairs and must necessarily open to a common hall or corridor It is recommended to have a threshold of a...

Page 6: ...stones facilitates cleaning It is inconvenient to keep flammable combustible and easily flammable materials in the boiler room Installation site dimensions The boiler room should be in dimensions to...

Page 7: ...ed Under no circumstances should more than one boiler be connected to the same chimney Cylindrical chimney can be passed through the chimney in the figure Smoke chimneys should not be placed on the ou...

Page 8: ...water should not be added directly to the overheated boiler for cooling purposes This can cause noise in the installation excessively high thermal stresses in the boiler and thus permanent damage The...

Page 9: ...ot dipped or c It should be done with solid copper rod electrodes Copper rod electrodes must be at least 1 5 m tall with a diameter of 16 mm or a length of at least 1 25 m with a diameter of 20 mm and...

Page 10: ...P a g e 9 KYP YP Automatic Fuel Loading Central System Heating Boiler Usage and Maintenance Manual Electrical Wiring Diagram...

Page 11: ...onstruction and connection of the chimneys are important in terms of high combustion efficiency low heating cost and protecting the environment In order for the combustion to be good the chimney must...

Page 12: ...west level of the chimney there should be a cleaning cover made of all kinds of sealed steel The length of the flue gas pipe between the chimney and the boiler should not exceed one quarter of the chi...

Page 13: ...tion Pot It is the place where the fuel mixes with the air and returns to the flame Fuel comes from inside the double walled structure and air comes from outside Ignition takes place from the ignition...

Page 14: ...600x600 FUEL CAPACITY kg 200 280 330 WATER VOLUME lt 320 400 480 560 640 890 925 1240 1195 1505 1570 BOILER WEIGHT kg 805 920 1080 1155 1300 1755 1900 2130 2200 2505 2750 NECESSARY DRAFT mbar 0 30 0 3...

Page 15: ...volume increases by 3 55 of its initial volume Expansion tanks are used to take this expansion depending on the temperature in the water Expansion tanks also fulfill the safety of the system that is...

Page 16: ...umber of floors applied The floor numbers given in the table are accepted as the boiler and expansion tank in the basement BOILER POWER SAFETY VALVE DIAMETER NUMBER OF FLOOR kW inch 1 2 3 4 5 6 7 8 9...

Page 17: ...tallation from rising above the atmospheric pressure The air in the system is evacuated by opening the vent pipes to the atmosphere from the expansion tank It is recommended to use separate expansion...

Page 18: ...d be checked daily and when it falls below the minimum value water should be added to the installation Open expansion tank volumes that should be according to nmak boiler capacities are given in the t...

Page 19: ...to turn the control panel on and off button It is used to enter a new value to the device It is used to increase or decrease the Fan Adjustment Temperature Adjustment Fuel Supply Fuel Standby values E...

Page 20: ...s activated and deactivated with this button Fan On Off The fan of the boiler is activated and deactivated with this button Manual Fuel Supply It is used to manually manually load fuel into the boiler...

Page 21: ...is not seen because the Gearbox On Off and Fan On Off buttons are not pressed and the boiler is operating Belli bir s re Red kt r On Off ve Fan On Off butonlar na bas lmazsa nce ate leme ve besleme ya...

Page 22: ...should be according to the boiler capacity and fuel type Press the Fuel Feed button to adjust the amount of fuel to be given into the boiler After setting the required feed setting from the buttons p...

Page 23: ...second figure As soon as you press the ENTER button the fan setting you have set will be memorized and the image on the screen will be as in the third figure Ignite the auxiliary materials you put in...

Page 24: ...capacities will vary according to values such as the degree of insulation in the environment heated by the boiler chimney draft thermal comfort demand of the space fuel diameter lower heating value Pr...

Page 25: ...If there is fuel dust or ashes collected between the fins of the fan it is necessary to clean it by blowing it without disturbing the fin structure of the fan or by holding a dryer Cleaning the boile...

Page 26: ...ing of plastic derived fuels in the boiler Chimney not heated Increase the temperature setting from the control panel Never throw plastic derived waste into the boiler or fuel tank bunker Check that t...

Page 27: ...f the control panel Activate the limit thermostat by pressing the red pin that comes out For boilers between KYP YP 130 250 as follows It is inside the control panel in boilers between 300 600 Fuel ex...

Page 28: ...Fuel Loading Central System Heating Boiler Usage and Maintenance Manual NL SOY YAPI MALZEMELER SANAY VE T CARET L M TED RKET zmir Pancar Organize Sanayi B lgesi 10 Cadde No 2 Torbal IZMIR TURKEY Tel...

Reviews: