ÜKYP/YP Automatic Fuel Loading, Central System Heating Boiler Usage and Maintenance Manual
Gearbox On/Off and
Manual Fuel Feed,
Fuel Feed and
Fuel Wait will not work.
The boiler does not operate because the
Gearbox On/Off and
Fan On/Off buttons are not pressed in the adjacent display.
It is useful to adjust the boiler water temperature to 60
o
C at the first start-up. For
this, first press the
Temperature Setting button on the panel.
TEMPERATURE SET will appear on the screen. You can press and hold
the buttons until you reach the temperature you want to set.
When it reaches the desired level, you can memorize it by pressing the
ENTER button.
Press the
Fan Setting button of the panel. A rectangle will appear around
the line in the upper left corner.
When you press the button once, it increases the fan level once more and
as in the second figure,
As soon as you press the
ENTER button, the fan setting you have set will be
memorized and the image on the screen will be as in the third figure.
Ignite the auxiliary materials you put in the boiler.
Then close the boiler covers tightly and press the
Fan On/Off button on
the panel. The Fan lamp on the top right of the control panel will turn on and the
boiler will continue to heat.
Pressing the
ON/OFF button will be sufficient to turn off the boiler. As long as the power is not
disconnected (power failure, unplugging the boiler), the pump will continue to run until the temperature
drops.
Increasing the fan speed more than necessary will cause some heat to be discharged
from the chimney. Air given suddenly and in large quantities during combustion will
cause sticking in the slags.
Boiler covers and hopper cover should not be left open during combustion.
In the first start-up, the ignition may fail because the flue temperature will heat up late