ÜKYP/YP Automatic Fuel Loading, Central System Heating Boiler Usage and Maintenance Manual
BOILER FEATURES
1. Control panel
5. Fuel reservoir (Hopper)
2. Combustion pot
6. Second pass smoke pipes
3. Fuel feeding auger
7. Third pass smoke pipes
4. Fuel dosing (rotary)
1.
Control Panel: It is the electronic box that controls the boiler. It controls when the reducer,
motor, fan, pump will stop and work. The temperature values read while controlling are
effective.
2.
Combustion Pot: It is the place where the fuel mixes with the air and returns to the flame. Fuel
comes from inside the double-walled structure and air comes from outside. Ignition takes
place from the ignition resistor next to the holes in the air chamber.
3.
Fuel Feeding Auger: It provides the transmission of the fuel to the combustion pot.
4.
Fuel Dosing Unit (Rotary): It allows a certain amount of fuel to fall
on the auger. Another and main task is to provide air tightness
between the combustion pot and the bunker and to ensure
safety.
5.
Fuel Reservoir (Hopper): It is the reservoir where the fuel is
stored. The capacity it can take may vary depending on the fuel
size.
Rotary