Well-ventilated o
ffi
ce (recommended) or clean, light-duty manufacturing
Operating
Temperature
50ºF (10ºC) to 95ºF (35º C) capable
73ºF (22ºC) to 77ºF (25º C) for best performance
Storage Temperature
50ºF (10ºC) to 95ºF (35º C)
Operating Humidity
Non-condensing
Electrical Power
Single Phase 110/240V AC, 10/5 Amp, 50/60 Hz
Grounded (earthed) and stable (surge and spike protected)
Particulate/Odor
Outside Ventilated
Exhaust System
High-pressure vacuum blower capable of:
150 CFM (cubic feet per minute) @ 6 inches
static pressure (255m3/hr at 1.5kPa)
250 CFM (cubic feet per minute) @ 6 inches
static pressure (425m3/hr at 1.5kPa)
Computer
Requirements
(See the Installation & Set-up
Guide for more information)
Windows XP or Windows Vista (32 and 64 bit)
2.0 GHz Processor (minimum)
1 GB of RAM (minimum)
40 GB Hard Drive (minimum)
Software
Requirement
Graphics or CAD based
Laser Safety
CO
2
Laser, Interlocked Safety Enclosure = Class 1
Red Diode Pointer = Class 2
6
Summary of Contents for VLS2.30
Page 1: ...VLS Desktop User Guide VLS2 30 VLS3 50 www ulsinc com Revision 2012 08...
Page 5: ...Chapter 1 Specifications 5...
Page 8: ...Chapter 2 Safety 8...
Page 9: ......
Page 15: ......
Page 16: ......
Page 19: ...Chapter 3 Installation 19...
Page 36: ...Chapter 4 Operation 36...
Page 62: ......
Page 68: ...Chapter 5 Accessories 68...
Page 80: ...Example Connection for PNP mode Example Connection for NPN mode 80...
Page 92: ...Chapter 6 Maintenance 92...
Page 99: ...www ulsinc com...