![Unitrol TROLL 3100 Manual Download Page 9](http://html1.mh-extra.com/html/unitrol/troll-3100/troll-3100_manual_845416009.webp)
9
Guide cursor to position 10 (fig.6) with keys 17, 18, 19, 20 (fig.1). It is choice between automatic
and manual start.
-
AUTOMATIC START
- by means of keys
or
setting iconrepresenting pictogram
D
)
)
)
)
)
.
Balancing machine comuter will be then programmed for automatic start. In this case,
parameters of the wheel, mounted in the chuck, will be entered in machine memory during
wheel guard closure and after closing the guard the machine will start automatically, measure
unbalance value, stop the wheel and display measurement results.
- MANUAL START-
by means of keys
or
setting in position 10. Balancing machine
computer will br then programmed for manual start. In this case, parameters of the wheel to be
balanced are entered to machine memeory, as described in items 8.3.1. - 8.3.3.
Above is concerning balancer TROLL 3105 Automatic start in balancer TROLL 3100 is setting
other way. The change of mode starting will be realized by simultaneous pressing the button
and button
. If will show inscription AUT in position „10” (fig 6). The automatic
starting will be connected after a closing of guard. If the inscription AUT isn”t shown. It means that
machine is programming in manual start. The engine is connecting after pressing the button
.
Fig 6
item 1
item 2
item 3
item 4
item 5
item 6
item 7
item 8
item 10
Summary of Contents for TROLL 3100