Transistor-Servo-Drive TVD6.2-RS
16
Connection at 400 V mains
AC or three-phase voltage supply
autotransformer or isolation transformer
one transformer for several devices
Notice:
-set safety contacts on transformer inrush current.
-slow fuses in front of the transformer
-fuse value corresponding to the transformer rated current
-quick fuses after the transformer
-fuse value for each power supply unit max. 30AF
Transformer capacity:
primary voltage
500V~
secondary voltage 400V~
Autotransformer
transformer rated power [VA]=
0,2
x
400
x
IM
x
GLF
x
nF
Isolation transformer
transformer rated power [VA]=
1,25
x
430
x
IM
x
GLF
x
nF
IM = total power of the motors
GLF = coincidence factor
nF
= speed ratio factor
GLF =
nF =
1
with one motor
effective speed
0,5 ... 0,7
with 2 motors
maximum speed
0,4 ... 0,6
with >2 motors
AC
three phase current
M
a
in
s
C
o
n
n
ec
tio
n