Transistor-Servo-Drive TVD6.2-RS
24
Ready for operation- BTB signal
Relay RL2
signal contact
X2:21 - X2:22
contact values
max. 48V, 0.5A
The ready for operation signal (BTB) shows the control (CNC/SPS)
that the drive is in working order.
Connect BTB-signals of several axes in series.
delay after switching on the mains >>> max. 1sec.
Indication
ready for operation
LED D1A bright
contact closed
error
LED D1A dark
contact open
BTB turns off with
individual error
BTB-LED D1A
single signal- LED
actual value error
dark
LED D2H bright
overtemperature
dark
LED D2G bright
short, line-to-earth fault dark
LED D2F bright
voltage error
dark
LED D2B bright
buffer circuit error
dark
LED D2A bright
Caution:
In any case use BTB-contact with CNC/SPS -Control !
Analogue measuring outputs
function
motor currency
speed
connection
X2:20 - X2:24
X1:6 - X1:7
measuring
2,5V= current limit
tachometer vol-
tage
value
5,0V= peak current
before divider
unipolar positiv
bipolar
Output-
Resistance
1 k
W
4,7 k
W
C
o
n
tro
l
C
o
n
n
ec
tio
n
s