TVD6.2-400-x-RS
27
C
o
n
n
ec
to
r
Pl
a
n
Control Connector X4
(front panel)
Function
Pin-No.
1st nominal value according to
the differential amplifier
X4: 1
2nd nominal value according to
the diff. amplifier or integrator
X4: 2
I-nominal value
X4: 3
+10 V
X4: 4
-10 V
X4: 5
I-actual value
X4: 6
n-actual value (normalised)
X4: 7
enable
X4: 8
device ground GND
X4: 9, 10
Power connection X3
Function
Terminal No.
Intern.Connector
No.
intermediate circuit ex. load resistor
X3:1
X31: 18,2 0 abc
intermediate c
X3:2
X31: 14, 16 abc
power L1
400V~
X3:3
X31: 10, 12 abc
power L2
400V~
X3:4
X31: 6, 8 abc
power L3
400V~
X3:5
X31: 2, 4 abc
earth PE
X3:6
motor 1
X3:7
X31: 22, 24 abe
motor 2
X3:8
X31: 26, 28 abe
motor 3
X3:9
X31: 30, 32 abe
3 Electrical Installation