Classic P3 x/x - 240-840A
20
Constant field
Connection
Plug-in terminal connectors
Input
X5:17, X5:18
Field
negative
X5:19
Field
positive
X5:20
Signal contact
X5:21, X5:22
Field voltage
Power supply
Field supply
230V~
210V=
400V~
360V=
Variable
0.9 x transformer secondary voltage
with auto-transformer
Field current
max. 10A=
Internal fuses
2 x 10AF
Cross-section -connecting line
min. 0.5mm²
External protection
line protection, min. 10A
Field current watchdog
Operating current
700mA
Signal contact
48V/0.5A
Connection
X5:21, X5:22
Error
open contact
Controlled field
Optional field current controller P3-F
Observe Manual P3-F
Field current control
Field voltage
max. 320V=
Control range
200mA to 10A
Combination of field/armature control
Field triggering circuit
Internal potential-free armature voltage measuring
Field voltage
max. 320V=
Control range
200mA to 10A
Triggering pointU
A
max. 450V=
Adjustments
min./max. field current
control parameter
EMC:
for a controlled field
>>>
use shielded field lines
Field current
signal contact
field
Fie
ld
co
n
n
ec
tio
n