3 Electrical Installation
P3 240-840A
19
Motor connection
Connection
positive command value
Motor-
bolt X10:13
Motor+
bolt X10:10
Note:
Armature choke only for a few applications
Inductance:
L [mH] = U
A
/I
A
x 0.8
Standard version without a choke
Motor lines have to be shielded.
Unit P3 x/x-
Type current
Choke
*
Direct current
Min. Conductor
cross-section (mm²)
240
UI180B250
70
360
UI210C400
150
480
UI240C500
240
840
UI240-7000
500
* Chokes are necessary only for special applications, e.g. quiet motor operation
(stage technique)
Switching in the armature circuit
- dc circuit current-free
- disable inactive
Warning
:
Faulty switching will create arcing across the switch contacts.
Power supply failure - brake resistor
Break contact of the mains contactor K1
Rating:
Resistor RNB = max. armature voltage/2 x type current
Attention:
Power lines have to be shielded and routed separately from control lines!
For electro-magnetic interferences please refer to the CE advice.