Control ports
Version: 2021 / V2
Page: 38
BAMOCAR-PG-D3-700/250, 400
4.5
Analogue inputs ±10 V
Entrance
Connection
Basic function
Voltage
Status
Parameter
AIN1+, AIN1-
X1:H, X1:J
Speed setpoint
± 10 V
prog.
AIN2+, AIN2-
X1:P, X1:R
Current limit
2. speed setpoint
± 10 V
prog.
Properties
Differential input
AIN1+ / AIN1-
AIN2+ / AIN2-
Input resistance
70 kΩ
Voltage limit
±12 V
Resolution
11 bit + sign
The direction of motor rotation can be changed by swapping the +/- connections on the differential
input, by a logic input or by programming (see NDrive-x).
The analogue inputs can be assigned to different functions (see NDrive-x).
The analogue input AIN1 can be programmed as an external analogue speed limit and the analogue
input AIN2 can be programmed as an external analogue current limit.
4.6
Analogue output - not available
There is no analogue output in this BAMOCAR variant.