Electrical installations
Version: 2021 / V2
Page: 31
BAMOCAR-PG-D3-700/250, 400
3.7
Power connections
PG cable gland
Metal M25 x 1.5 with shield contact
Connection - battery positive pole
Connection - Motor W
Connection - Motor V
Connection-- Motor U
Connection - battery negative pole
Connection cable maximum 50 mm2
Structure:
Only use cables with shield layer!
Connection example:
Adapt dimensions to the cable and cable gland used!
Remove outer insulation to 34... 38 mm, shorten shield layer to 10 mm.
Shorten inner insulation. Copper strands 7..12 mm.
Cable lug insulation 25 mm (fabric hose or
shrink hose).
Cable lug for M10 screw.
Push on the PG screw connection with shield springs.
Slide on the cable shoe insulation.
Press the cable strands into the cable lug (15 mm).
Screw in the PG gland in the unit.
Screw cable lug onto the internal busbar. Tighten the cap of
the PG screw connection.
Tighten the cable gland on the cable lug.
Connection screw
: M10 x 12 (self-locking or corrugated washer, no toothed lock washer)
Maximum tightening torque 20 Nm
Remark:
The cable gland is not included in the scope of delivery.