Run 1.xlsm
Client: USSC
Job #: 22-753
Model: KP5522
Tracking #: 121
Run #: 1
Technician: SJB
Date:
Particulate Sampling Data
Elapsed
Time
(min)
Gas Meter
(ft
3
)
Sample
Rate (cfm)
Dilution
Tunnel dP
(in H
2
O)
Orifice
dH
(in H
2
O)
Meter
Temp (°F)
Meter
Vacuum
(in Hg)
Pro. Rate
(%)
Scale
Reading
Weight
Change
Dilution
Tunnel
Flue
Filter
Ambient
2/18/2022
BOX A TEST DATA - ASTM E2779 / ASTM E2515
Fuel Weight (lb)
Temperature Data (°F)
340
64.336
0.190
0.031
1.49
60
-1.57
101
0.7
0.0
81
212
71
67.5
341
64.526
0.190
0.030
1.50
59.9
-1.56
102
0.7
0.0
81
211
71
67.5
342
64.717
0.191
0.030
1.48
60.1
-1.55
103
0.7
0.0
81
210
71
67.6
343
64.906
0.189
0.031
1.49
60.3
-1.62
100
0.6
-0.1
81
211
71
67.6
344
65.095
0.189
0.030
1.49
60.3
-1.56
102
0.6
0.0
81
210
71
67.5
345
65.285
0.190
0.031
1.49
60.3
-1.71
100
0.6
0.0
81
211
71
67.5
346
65.474
0.189
0.031
1.49
60.3
-1.49
100
0.5
0.0
81
212
71
67.5
347
65.663
0.189
0.031
1.49
60.3
-1.67
100
0.5
0.0
81
210
71
67.5
348
65.853
0.190
0.030
1.49
60.5
-1.6
102
0.5
0.0
81
208
71
67.5
349
66.042
0.189
0.030
1.47
60.5
-1.63
101
0.4
-0.1
81
211
71
67.8
350
66.232
0.190
0.030
1.51
60.4
-1.56
102
0.4
0.0
81
213
71
67.7
351
66.423
0.191
0.029
1.49
60.3
-1.72
104
0.3
0.0
81
212
71
67.6
352
66.612
0.189
0.030
1.49
60.4
-1.67
102
0.3
0.0
81
211
71
67.7
353
66.801
0.189
0.030
1.48
60.2
-1.53
102
0.3
-0.1
81
209
71
67.7
354
66.989
0.188
0.030
1.49
60.3
-1.53
101
0.2
0.0
81
211
71
67.9
355
67.178
0.189
0.029
1.47
60.2
-1.73
103
0.2
0.0
82
213
71
68.3
356
67.367
0.189
0.030
1.49
60.5
-1.57
102
0.1
0.0
82
212
71
68.3
357
67.556
0.189
0.030
1.49
60.6
-1.5
102
0.1
0.0
82
212
71
68.4
358
67.747
0.191
0.031
1.48
60.5
-1.52
101
0.1
0.0
82
212
71
68.6
359
67.936
0.189
0.030
1.48
60.7
-1.72
102
0.0
0.0
82
215
71
68.6
360
68.125
0.189
0.030
1.49
60.9
-1.73
101
0.0
0.0
82
215
71
68.8
Avg/Tot
68.125
0.189
0.031
1.49
63
-1.53
100
83
250
72
68
PFS-TECO
Page 20 of 32
Summary of Contents for KP5522-P
Page 11: ...Project 22 753 Model KP5522 Page 10 Appliance Front Appliance Left...
Page 12: ...Project 22 753 Model KP5522 Page 11 Appliance Right Appliance Rear...
Page 14: ...Project 22 753 Model KP5522 Page 13 Pellet Fuel Analysis...
Page 17: ...Project 22 753 Model KP5522 Page 16 Sealed Unit...
Page 19: ...Appendix A...
Page 66: ...Project 22 751 Model Charnwood Skye E700 Page 16 Tunnel Schematic...
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ...Appendix B...
Page 127: ...2022 United States Stove Company 23 NOTES...
Page 128: ...24 2022 United States Stove Company NOTES...
Page 129: ...2022 United States Stove Company 25 NOTES...
Page 160: ......
Page 161: ......
Page 162: ......
Page 163: ...Appendix C...
Page 171: ......
Page 172: ......
Page 174: ......
Page 175: ......
Page 181: ......
Page 182: ......
Page 189: ...Appendix E...
Page 192: ...1 1 2 2 3 3 4 4 A A B B A B C...