T7 Topside Initial Confi guration
10
T7 Con
fi
guration Code Chart
Code 1
: Jet-1 Button Con
fi
guration
Option 1: Jet-1 button operates Hi-Speed Pump-1
Option 2: Jet-1 button operates Lo-Speed and Hi-Speed Pump-1
Code 2
: Jet-2 Button Con
fi
guration
Option 1: Jet-2 button operates Lo-Speed Pump-1
Option 2: Jet-2 button operates Hi-Speed Pump-2
Option 3: Jet-2 button operates Lo-Speed and Hi-Speed Pump-2
Code 3
: Aux Button Con
fi
guration
Option 1: Aux button used only for programming
Option 2: Aux button used for Air Blower w/ Purge*
Option 3: Aux button used for Air Blower (no Purge)
Option 4: Aux button operates Hi-Speed Pump-3
Code 4
: Power (Amperage) Con
fi
guration
Option 1: 50A Operation (No heat with Aux)
Option 2: 60A Operation (No power restriction)
Option 3: 50A Operation (No heat with P-2)
Option 4: 40A Operation (No heat with P-2, and Aux)
Option 5: 20A 120V Operation or 30A 240V Operation
(No heat with anything other then P-1 Lo-Speed)
Code 5
: Heater Operation
Option 1: Electric Heater operates with Lo-Speed Pump-1
Option 2: Electric Heater operates with Circulation Pump
Option 3: No longer used **
Option 4: Electric Heater operates with Timed Circulation Pump ***
*
*
- The Air Blower will engage (purge) for a minute during
fi
ltration to push any
stale water out of the blower’s plumbing and back into the spa for
fi
ltration.
** - On newer units, this option is no longer selectable.
*** - When setting Code 5 to Option 4 it is important to make sure that Pump-1
is wired as a single speed (Hi-Speed) pump - and not connected to the
red (Lo-Speed) wire. In addition the Circulation Pump cord will need to be
recon
fi
gured to use the receptacles red wire for the power line going to the
circulation pump.
Summary of Contents for T7