3.2 CHARGING YOUR ELECTRIC VEHICLE (EV)
3.2.1 Connect and Charge
3.2.2 Stop Charging
3.2.3 Self-Monitoring and Recovery (Auto Restart)
a. Insert the charging Connector into the EV and ensure the connector is fully seated/locked
in place.
b. Once complete, the charging session will commence.
a. Simply unplug the charging station connector from the EV at any time (once the connector
button is depressed, the charging session terminates immediately).
b. Return the connector to the holder.
When a charging session is interrupted due to a temporary error condition, the charging
station will automatically restart charging when the cause of the temporary error condition
returns to normal. The status indicator lights remain flashing RED until the error condition
is resolved.
• Temporary error conditions include: Over Current, Under Voltage, Missing Diode, Ground
Fault, and Over Temperature.
• For Over Current (OC) conditions: The charging session will be stopped while OC occurs.
After recovery from OC for 30 seconds, the charging station will automatically restart charging
for four times.
• When charging session stopped due to the Ground Fault (GFCI) trip, the charging station
will try to restart after 15 minutes for 4 times. After 4 times, the charging station buzzer will
stay on continuously, and status indicator will stay RED. The user should plug-out and plug-in
the power cable of the charging station.
Figure 3-1. Connect the charging plug to the EV
22