U N I Q U E U G P 6 F
3
Installation and Operating Instructions
Installation
For best performance at high ambient temperatures, there must be free air
circulation over the cooling unit at the rear of the freezer.
Ensure that there is a free air space above the freezer and that the flue (chimney) on
top of the cabinet is not covered in any way. Do not place the freezer in a space
where air circulation is restricted. Follow “clearance” instructions.
This free-standing freezer requires accessibility to the back for servicing the gas
equipment, which can be obtained by using a certified Flexible Metal Connector to
allow the freezer to be withdrawn without disrupting the gas supply. “Where a
flexible metal connector is used, it must comply with local authorities and in Canada
with the provisions of the current Standard CAN 1-6.10, Metal Connectors for Gas
Appliances”. However, if the Local Authorities require a rigid gas supply connector,
the freezer should be located with sufficient space at the back for servicing or, if
located against a wall a removable panel of a minimum size of 16” x 20” should be
provided in the wall to allow access to the rear of the freezer.
If you purchased a
CM (CO Monitor model) you must follow instructions in Section 7 - 5.0
onward.
While using on electrical operation this unit can be used in an enclosed area but must still
be protected from moisture as comply with all clearances.
For installation, proper clearances from combustible material to the freezer, the following
minimum clearance must be observed.
Chapter
2