U N I Q U E U G P 3 0 G
19
Top Burner Height
Oven Valve
The oven control has a flame safety device built into the body of the thermostat.
Presence of a gas ignition source (pilot) is verified by a flame safety probe. This
flame safety probe actuates the internal safety device to allow gas into the oven
burner when the oven is turned on. If there is a loss of gas ignition during operation,
the flame safety device will close off gas flow to the oven burner and pilot.
The oven burner orifice is located on a brass injector stud at the rear of the oven
under the oven floor. This orifice is dedicated to the gas for which the oven is to be
used. The orifice is not adjustable. It must be changed completely to convert from
one gas to the other. DO NOT DISCARD THE UNUSED ORIFICE. It should be
saved in order to convert the range back to its original fuel
Oven Pilot
The oven pilot is located along the left hand side of the oven burner. It is fastened to
the pilot assembly with the thermocouple and the electrode. The flame of the oven
pilot ignites main burner gas when the oven is turned on. If the pilot flame is not
present, the flame safety device will not allow pilot gas or main burner gas to flow.
Oven Pilot
Pilot Orifice
In
the
pilot
assembly
shown
below,
the
LPG
orifice
is
0.14
mm.
When
doing
the
conversion
from
Propane
to
Natural
gas
make
sure
the
pilot
orifice
is
changed
to
the
NG
orifice
sized
at
0.2
mm.
If
you
leave
the
LPG
orifice
0.14mm
in
place,
the
pilot
flame
will
may
be
too
small
to
keep
the
pilot
lit.