U N I Q U E U G P 3 0 G
16
7.
Replace the cap back on the regulator
8.
Next you will remove the grates, burners and burner caps from the range to
access the orifices.
9.
You will need a 7mm wrench to remove the orifices. Each orifice can be accessed
easily - the larger burner orifice is located on the burner wall.
10.
Remove all LPG orifices: place in the bag and store in a safe place.
11.
Take the NG orifices provided and install them as shown below
See below for rating of orifice for each model
Smallest
Medium
x
2
Largest Oven
NG .8
mm 1.35mm 1.50mm 1.9mm
12.
Once all the orifices are installed, replace all burners and burner caps, then fire up
the burners to check the minimum flame height.
13.
Minimum flame height should be approx. ¼” tall. There is a small adjustment
screw located on the valve itself. The lid and the front control panel must be
removed to accomplish this adjustment.
14.
Turn the valve fully counter clockwise. Then proceed to adjust the adjustment
screw counter clockwise for a smaller flame and clockwise for a larger flame.
Adjustment. Minimum flame should be approx. ¼” tall
Orifice Location
Adjustment location is
inside the valve stem