45
6
WEIGHING SETTING AND OPERATIONS
45
W
EI
G
H
IN
G
S
ET
TI
N
G
A
N
D
O
PE
R
A
TI
O
N
S
Chapter
6
- Time chart in discharging control mode
*
1
: Determine the stable condition by stable detection mode (weighing function 2 in setting mode
1-5) and motion detection (setting mode 2-3).
*
2
: To hold weight values, there is a need to set the auto hold mode (weighing function 1 in setting
mode 1-4) to 1(Valid) in advance.
In discharging control mode, weight values are held for the complete output time only under the
above conditions. Determine complete output time t3 by setting mode 1-3 (Input range/0.0 - 9.9
sec).
0
Near zero
Final
-
Set point 2
Final
-
Compensation
Final
NET
Time
Stable
Near zero
TARE
Comparison
Judging timer
ON
ON
ON
ON
ON
OFF
SP2
SP3
Complete
ON
Complete output timet3 (Hold)
Judging time t2
ON
(STAB)
(NZ)
(COMPL)
Comparison inhibit time t1
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Final
-
Set point 1
SP1
ON
OFF
Comparison inhibit time t1
inhibit timer