44
6
WEIGHING SETTING AND OPERATIONS
44
W
EIG
H
IN
G
S
ET
TIN
G
A
N
D
O
PE
R
A
TIO
N
S
Chapter
6
- Comparison inhibit time (setting mode 1-1)
Input range/0.00 - 9.99 (sec.)
In discharging control mode, comparison can be inhibited for a fixed time to prevent inappropriate
control operation by mechanical vibrations associated with valve opening and closing.
Comparison inhibit time works from when the weight value reaches (final - set point 1), (final - set
point 2).
- Judging time (setting mode 1-2)
Input range/0.0 - 9.9 (sec.)
In a manner similar to comparison inhibit time, comparison judgment is inhibited for a fixed time to
prevent inappropriate judgment by mechanical vibrations associated with valve opening and
closing. Judging time works from when the weight value reaches (final - compensation).
- Comparison timing (setting mode 1-4 weighing function 1)
Determine the timing of the complete signal output.
0
Final
-
Set point 2
Final
-
Compensation
Comparison inhibit time
Judging time
Final
-
Set point 1
* Stable condition indicates a state in which " " is lit (stable state).
Comparison timing
0: ON from when the judging timer has elapsed.
1: ON from when stable condition is established
after the judging timer has elapsed.
2: ON from when the judging timer has elapsed or
from when stable condition is established.
Weighing function 1