4.Communication Connector
2
Measurement work selection:
Select the method of specifying measurement work.
Control input selection:
Select the method of specifying control (SECTION signal, T/H
signal, GRAPH TRIG signal) input.
Setting range: Communication
Specifying by external input is disabled, and
specifying by CC-Link is enabled.
External input
Specifying by CC-Link is disabled, and
specifying by external input is enabled.
Initial value:
External input
How to set
4.
Communication Connector
Each meaning of signal line represents each signal type as
follows: SLD and FG are connected inside.
Suitable plug for the connection is the plug made by WAGO
CO., Ltd. or equivalent one. (Accessories)
Operating method
Name
Signal Type
DA
Signal line DA side
DB
Signal line DB side
DG
Signal line Ground
SLD
Shield
FG
Frame Ground
SET.
→
→
System Setting
Operation
→
Page 3
Settings of Mitsubishi (general-purpose) PLC CPU unit.
When you use Mitsubishi (general-purpose) PLC MELSEC-Q series, set up master
station network parameters as follows.
・
CC-Link mode setting
:
Remote net Ver. 1 mode.
・
Station type
:
Remote device station
(Station information settings
→
Station type)
Cautions
- Pick up the plug and operate the lever with a
thumb.
- For the protection from the damage, do not
operate the lever without removing the plug.