21
5.
General Specification
•
Automatic selection of the measuring range of the measuring
function.
•
Full range overload protection.
•
The maximum allowable voltage between the measuring end and the
ground: 600V DC or 600V AC.
•
CAT III 600V
•
Working height: the maximum altitude is 2000m.
•
Display: LCD.
•
Maximum display value: 5999.
•
Polarity indication: automatic indication, "-" indicates negative
polarity.
•
Over range display: "0L" or "-0L".
•
Sampling time: about 3 times/second, about 10 times/second for
simulation strip.
•
Unit display: display of function and electricity unit.
•
Automatic shutdown period: about 10 minutes.
•
Power supply: 1.5V SIZE AAA battery × 3
。
•
Data hold displayed as: ' '.
•
Battery undervoltage indication: "
" displayed on the LCD.
•
Temperature coefficient: less than 0.1 × Accuracy/
℃
.
•
Maximum jaw opening size: 23 mm.
•
Working temperature: 5
℃
~
35
℃
.
•
Storage temperature: - 10
℃
~
50
℃
.