C.I.B. UNIGAS - M03957CI
43
Replacing the spring in the gas valve group
To replace the spring in the gas valve group,proceed as follows:
1
Carefully twist the protection cap 1 and the O-ring 2.
2
remove the “set value” spring 3 from housing 4.
3
Replace spring 3.
4
Carefully insert the new “set value” spring. Pay attention to mount properly. First insert the spring part with smaller diameter in the
housing.
5
Place O-ring 2 in protective cap 1. Screw in the protective cap with the O-ring in it.
6
Stick the adhesive label for spring identification on the type plate.
Removing the combustion head
1
Remove the top
H
.
2
Disconnect the electrode cables
CE
.
3
Remove the
UV
detector out of its housing: disconnect electrode cables and the light oil flexible hoses.
4
Loosen the screws
S
holding the
VR
group: screw the VR screw in order to loose the threaded rod
C
.
5
Loosen the screws
V
holding the gas manifold
G
, loosen the two connectors
E
and remove the assembly as shown.
6
Clean the combustion head by means of a vacuum cleaner; scrape off the scale by means of a metallic brush.
Note:
to replace the combustion head, reverse the operations described above.
DUNGS MBC..SE
SKP Siemens actuator
3
1
2
4
4
1
1
3
H
V
E
V
E
CE
H
G
C
Summary of Contents for HP60
Page 9: ...C I B UNIGAS M03957CI 9 Overall dimensions mm Boiler recommended drilling template ...
Page 49: ...C I B UNIGAS M03957CI 49 ...
Page 51: ...C I B UNIGAS M03957CI 51 WIRING DIAGRAM Cod 05 680 Progressive burners ...
Page 52: ...C I B UNIGAS M03957CI 52 WIRING DIAGRAM Cod 05 681 Fully modulating burners ...
Page 54: ......
Page 55: ......
Page 56: ......