SERVICE AND INSTALLATION MANUAL
Ice Maker Installation
Normal operating ambient temperature should be between 40˚F (4.4˚C)
and 110˚F (43.3˚C). Normal operating water temperature should be
between 40˚F (4.4˚C) and 90˚F (32˚C). Operation of the ice maker for
extended periods outside of these normal temperature ranges may
affect production capacity
•
IT IS STRONGLY RECOMMENDED TO USE A WATER FILTER. A FILTER, IF IT IS OF THE PROPER TYPE, CAN
REMOVE TASTE AND ODORS AS WELL AS PARTICLES AND CAN PROLONG THE LIFE OF THE MACHINE.
• The ice maker must be installed with all electrical and water connections in accordance with state
and local codes
• The unit should be located on a firm and level surface. It is important for the ice maker to be level in
order to work properly If needed, you can adjust the height of the ice maker by rotating the feet
See the Leveling the Ice Maker section
ELECTRICAL REQUIREMENTS
Plug into a grounded 3-prong outlet
Never remove the grounding prong from the plug
Never use an adapter
Never use an extension cord
Failure to follow these instructions can result in fire,
electrical shock or death
Before you move your ice maker into its final location, it is important to make sure you have the proper
electrical connection A standard electrical supply (
115 VAC, 60 Hz
, 15 A), properly grounded in
accordance with the National Electrical Code and local codes and ordinances, is required The ice
maker should always be plugged into its own individual electrical outlet It is recommended that a
separate circuit, serving only your ice maker, be provided Use receptacles that cannot be turned off
by a switch or pull chain The fuse (or circuit breaker) size should be 15 amperes
Recommended grounding method
For your personal safety, this appliance must be grounded It is equipped with a power supply cord
having a 3-prong grounding plug To minimize possible shock hazard, the cord must be plugged into a
mating 3-pronged and grounding-type wall receptacle, grounded in accordance with the National
Electrical Code and local codes and ordinances If a mating wall receptacle is not available, it is
the personal responsibility of the customer to have a properly grounded, 3-prong wall receptacle
installed by a qualified electrician.