106
•
Edit Frequency
— Enter the desired frequency that the scanner should
monitor for the tone-out.
•
Set Modulation
— Set the modulation type for the paging signal. Next
choose the modulation setting:
•
Auto
— The scanner uses the default modulation for the frequency band. If
the default modulation is AM, WFM, or FMB, the modulation operates as
FM.
•
NFM
— The scanner uses NFM modulation.
•
FM
— The scanner uses FM for the frequency band. This is the default
setting.
•
Set Attenuator
— Press
F
then turn the
Scroll Control
to
select
On
or
Off
.
Set Tone
— Sets the audio tone frequency for the page. Then choose the Tone
setting.
•
Edit Tone A
— Set the audio frequency for Tone A
•
Edit Tone B
— Set the audio frequency for Tone B
Notes:
• For two-tone pages, enter a value for A and B.
• For one-tone pages using short tones of less than 3.75 seconds, enter the tone
value for A, and 0 (zero) for B.
• For long-tone pages, such as group pages of more than 3.75 seconds, enter 0
(zero) for A and the tone value for B.
Set Delay Time
— Sets the time the scanner remains in monitor mode after the
scanner receives a page and the carrier drops.
•
1-5 sec
— the scanner resumes standby mode after the carrier drops and
the selected time expires.
•
Infinite
— you must press
[HOLD/RESUME]
after a page to resume
standby mode.
•
Off
— the scanner resumes standby as soon as the carrier drops after a page.
Set Alert
— Sets the alert the scanner uses when it receives an alert.
•
Alert 1
-
9
— scroll to select the alert tone pattern, The scanner sounds
each alert as you scroll to its numbered value.
•
Off
— the scanner does not sound an alert.
UB356ZH.fm Page 106 Wednesday, December 19, 2007 11:28 AM