NVRAM Options
Setting
Description
Result codes
Q0
Enabled
Verbal or numeric result codes
V1
Verbal result codes
Result code subset
X1
Basic
Profile used at reset
Y0
At reset use stored profile 0
Protocol response codes
&A1
ARQ protocol codes
Serial port rate select
&B0
Variable serial port rate
Guard tone
&G0
U.S./Canada
Transmit data hardware flow
control
&H0
Disabled
Received data software flow
control
&I2
No pass-thru
Analog data compression
&K1
Enabled
Error control/sync
&M4
Normal/error control
Highest Link rate select
&N0
Variable
Pulse dialing type
&P1
U.S., Canada, and other countries
Received data hardware flow
control
&R1
Disabled
Data Set Ready
&S0
Always on
Remote Digital Loopback (RDL)
&T5
Deny RDL
Lowest Link rate select
&U0
Variable
Break handling
&Y1
Clear buffer, send immediately
Set Compression Method
+DCS=1,0
Enable V.42bis, Disable V.44
Set Compression Report Mode
+DR=0
Disable the report
Set V.42 Compression Method
+DS=3,0,2048,32
Accept V.42bis, don’t disconnect
if fail, 2048 dictionary, 32 string
Set Break Handling Method
+EB=3,0,10
Expedited, destructive, 100mS
Set Error Control Reporting
+ER=0
Disable the report
Set Call Termination Buffer
Management
+ETBM=0,0,0
Flush all buffers on call
termination
Set Local Rate Reporting
+ILRR=0
Disable the report
Set Modulation Reporting Mode
+MR=0
Disable the report
Set Modulation Selection
+MS=V92,1,0,31200,0,56000
V.92, auto, auto, 31.2k max tx,56k
max rx
Set Compression Method
+DCS=1,0
Enable V.42bis, Disable V.44
Word length*
7
Parity*
1
Even