Programming setting
5 5
ANNEX A: Parameters table
The following is a table of the parameters. The values indicated in the column on the right refer to some of the existing
DATABASES which can undergo variations depending on the version.
Parameter
Menu
level
Description
Unit of
measurement
Admitted value
range
R1
Pr01
M-8-6-01
Maximum time of ignition cycle
second
5 - 25
Pr02
M-8-6-02
Start-up time
minute
2 - 12
Pr03
M-8-6-03
Time interval between two brazier cleaning operations
minute
3 - 240
Pr04
M-8-6-04
Time screw motor ON during ignition
phase
second
0,1 ... 8
Pr05
M-8-6-05
Time screw motor ON during start-up
phase
second
0,1 ... 8
Pr06
M-8-6-06
Time screw motor ON during working
phase at output 1
second
0,1 ... 8
Pr07
M-8-6-07
Time screw motor ON during working
phase at output 2
second
0,1 ... 8
Pr08
M-8-6-08
Time screw motor ON during working
phase at output 3
second
0,1 ... 8
Pr09
M-8-6-09
Time screw motor ON during working
phase at output 4
second
0,1 ... 8
Pr10
M-8-6-10
Time screw motor ON during working
phase at output 5
second
0,1 ... 8
Pr11
M-8-6-11
Alarm delay
second
20 ... 90
Pr12
M-8-6-12
Brazier cleaning duration
second
0 ... 120
Pr13
M-8-6-13
Minimum flow gas temperature to consider
heat stove on
°C
40 ... 180
Pr14
M-8-6-14
Flue gas temperature to switch to
ECO-MODULA mode
°C
110 ... 250
Pr15
M-8-6-15
Flue gas temperature threshold to switch on
the heat exchangers
°C
24 ... 90
Pr16
M-8-6-16
Flue gas intake speed during
ignition
rpm
500 ... 2800
Pr17
M-8-6-17
Flue gas intake speed during start-up phase
rpm
500 ... 2800
Pr18
M-8-6-18
Flue gas intake speed during working phase
at output 1
rpm
500 ... 2800
Pr19
M-8-6-19
Flue gas intake speed during working phase
at output 2
rpm
500 ... 2800
Pr20
M-8-6-20
Flue gas intake speed during working phase
at output 3
rpm
500 ... 2800
Pr21
M-8-6-21
Flue gas intake speed during working phase
at output 4
rpm
500 ... 2800
Pr22
M-8-6-22
Flue gas intake speed during working phase
at output 5
rpm
500 - 2800
Pr23
M-8-6-23
Heat exchanger 1 motor speed during
working at output 1
volt
65 ... 225
Pr24
M-8-6-24
Heat exchanger 1 motor speed during
working at output 2
volt
66 ... 225
20
R2
20
R3
20
R4
20
5
5
5
5
30
30
30
30
1
1
1
1
1,2 1,2 1,2 1,2
1,8 1,8 1,8 1,7
3,1 3,1 3,1 3,0
4,4 4,4 4,4 4,2
5,7 5,7 5,7 5,5
7
7
7
6,7
30
30
30
30
60
60
60
60
50
50
50
50
250 250 250 250
90
90
90
90
1000 1000 1000 1000
1100 1100 1100 1100
900 1100 1100 1100
1000 1100 1200 1200
1100 1200 1300 1300
1450 1550 1650 1650
1600 1700 1800 1800
130 130 130 130
150 150 150 150