14
2.5 - OPERATING DATA AND GENERAL FEATURES
for the adjustment data: NozzLES - PrESSurE - DIAGrAmS - fLoW rATES refer to the paragraph ADAPTATIoN To oTHEr
TYPES of GAS.
SPK
1000
Boiler category
I
2H
modulation ratio
1:2
rated heat output on P.C.I. Qn
kW
940
minimum heat output on P.C.I. Qmin
kW
470
rated useful power (Tr 60 / Tm 80 °C) Pn
kW
923,2
minimum useful power (Tr 60 / Tm 80 °C) Pn min
kW
460,1
rated useful power (Tr 30 / Tm 50 °C) Pcond
kW
1006
minimum useful power (Tr 30 / Tm 50 °C) Pcond min kW
508
rated power performance (Tr 60 / Tm 80°C)
%
98,2
minimum power performance (Tr 60 / Tm 80°C)
%
97,9
rated power performance (Tr 30 / Tm 50°C)
%
107
minimum power performance (Tr 30 / Tm 50°C)
%
108,1
Performance at 30% of the load (Tr 30°C)
%
108
Combustion efficiency at nominal load
%
98,4
Combustion efficiency with reduced load
%
98,7
Casing heat loss with burner operating (Qmin)
%
0,81
Casing heat loss with burner operating (Qn)
%
0,19
Net flue gas temperature tf-ta (min)(*)
°C
25,1
Net flue gas temperature tf-ta (max)(*)
°C
31,0
maximum permitted temperature
°C
100
maximum operating temperature
°C
95
Flue gas mass flow rate (min)
kg/h
790
Flue gas mass flow rate (max)
kg/h
1581
Excess air
%
29,54
Heat loss at chimney with burner on (min)
%
1,29
Heat loss at chimney with burner on (max)
%
1,60
minimum heating circuit pressure
bar
1
maximum heating circuit pressure
bar
6
Water content
l
1413
methane gas consumption G20 (pow.sup. 20 mbar) at Qn m
3
/h
99,4
methane gas consumption G20 (pow.sup. 20 mbar) at Qmin
m
3
/h
49,7
massima pressione disponibile base camino
Pa
100
max condensate production
kg/h
158
Emissions
Co at maximum heat output with 0% of o2
mg/kWh 2
Nox at maximum heat output with 0% of o2
mg/kWh 46
Nox weight with 3,5% of o2
mg/kWh 33
Electrical data
Power supply voltage/frequency
V/Hz
230 / 50 - 400 / 50
Protection rating
IP
-
room Temperature = 20°C
(*) Temperature detected with appliance operation flow rate 80°C / ret. 60°C
Co
2
(min/max) See table ‘’NozzLES - PrESSurE’’
Seasonal energy efficiency to heat the room
2009/125 CEE (<=400Kw)
η
s
- see table ErP
Heat loss in stand-by
∆T 30°C
- Pstb - see table ErP
Electricity consumption on standby - Psb - see table ErP
Summary of Contents for SPK 1000
Page 35: ...35 Maintenance instructions ENGLISH PAGE LEFT BLANC INTENTIONALLY ...
Page 42: ...42 ...
Page 43: ...43 ...