PERFORMANCE DATA
Erp DIRECTIVE
MODULEX
EXT 100 EXT 150 EXT 200 EXT 250 EXT300 EXT 350
Element
Symbol
Unit
Effective nominal output
Pnominale
kW
97
146
195
244
294
342
Seasonal energy efficiency to heat
the room
ƞ
s
%
92
92
92
92
92
92
Season efficiency class to
discharge
A
A
A
A
A
A
For boilers to heat the room
and mixed boilers: useful heat output
Useful heat output with
high temperature capacity
(Tr 60 °C / Tm 80 °C)
P
4
kW
97,2
146,1
195,2
244,5
294,0
341,7
Rated heat output efficiency
with high temperature capacity
(Tr 60 °C / Tm 80 °C)
ƞ
4
%
88
87,7
87,7
88,1
88,3
88,5
Useful power at 30% of the rated heat
output with low temperature
capacity (Tr 30 °C)
P
1
kW
32,2,
49,3
64,4
80,5
96,6
112
Performance at 30% of the rated heat
output with low temperature
capacity (Tr 30 °C)
ƞ
1
%
96,7
96,7
96,7
96,7
96,7
96,7
Boiler with output range adjustment:
YES / NO
NO
NO
NO
NO
NO
NO
Auxiliary electricity consumption
With a full load
elmax
kW
0,145
0,210
0,290
0,362
0,435
0,507
With a partial load
elmin
kW
0,040
0,040
0,040
0,040
0,040
0,040
Standby mode
P
SB
kW
0,010
0,010
0,010
0,010
0,010
0,010
Other elements
Heat dispersion on standby
P
stb
kW
0,787
0,94
0,98
1,10
1,15
1,39
Nitrogen oxides emissions
NOx
Mg/kWh
54
54
54
54
54
54
For mixed heating appliances
Declared load profile
-
-
-
-
-
-
Water heating energy efficiency
ƞ
wh
%
-
-
-
-
-
-
Daily consumption of electricity
Qelec
kWh
-
-
-
-
-
-
Daily consumption of fuel
Qfuel
kWh
-
-
-
-
-
-
Internal sound power level
Lwa
dB (A)
-
-
-
-
-
-
Seasonal DHW efficiency class
-
-
-
-
-
-
*
Appliances not covered by Directive 2009/15 / EC
Summary of Contents for MODULEX EXT 100
Page 1: ...E N G L I S H 100 150 200 250 300 350 INSTALLATION AND SERVICING INSTRUCTIONS MODULEX EXT ...
Page 32: ...32 Instructions for the installer THERMOSTAT FBR 2 CONNECTION room sensor ...
Page 33: ...33 Instructions for the installer MODULATING THERMOSTAT CONNECTIONS ...
Page 35: ...35 Instructions for the installer ...
Page 37: ...37 Instructions for the installer Sensor terminal assignments Terminal assignments BCM ...