39
ENGLISH
Installation Instructions
PARAMETER FA par 4.2
CODE
METHAN
PROPAN
Gt
0
1
PARAMETER FA par 4.2
TARATURA - ADJUSTMENT
CODE
MANUal
AUTOmatic
tt
0
5
Modify parameter FActory:
Once the
Gt
parameter has been edited
one must perform the
AUTOmatic
calibra-
tion (change parameter
tt)
EXAMPLE OF COMPILATION
- Perform calibration
AUTOmatic
cap. 4.4.1.
- when the conversion is complete, fill in the in
-
4.4 - ADJUSTMENT _TARATURA tA
Function / description of knobs and ‘’ D ‘’ key in calibration function
The Gas Valve does not provide mechanical calibra
-
tion; the minimum and maximum power settings are
then electronically performed through two parameters
(visible and modifiable during calibration):
-
P0
absolute minimum power; range 0 ÷ 100
-
P1
absolute maximum power; range 0 ÷ 100
There are two calibration methods:
- “
Manu”
allows an adjustment of the values around
the calibrated value (approxi/- 1.5 mbar).
It is activated with the procedure described in
section 4.4.1 (recommended procedure in most
cases).
-
“Auto”
allow reset of the previous values and the
complete calibration of the gas valve
(typical use
in case of valve replacement or gas transfor-
mation).
It is activated with the procedure shown
in section 4.4.2
MAX
M
IN
MAX
MIN
posizione per
diminuire
il valore
P0
potenza
minima
P1
potenza
massima
posizione
per memorizzare
il valore
posizione per
aumentare
il valore
tasto di
conferma /
scelta
formation required on the label supplied in the
documentation envelope and apply it next to the
technical data label of the boiler.
button of
confirmation /
choice
minimum
power
maximum
power
position
to set
the value
position to
decrease
value
position to
inecrease
value