Enter the FA parameters, after access code,
turn knob
“B”
to max until
“tt”
parameter is reached, press button
“D”
, modify
the value
00
in
05
by means of the
“C”
knob and then confirm by pressing the
“D”
button.
service
service
service
x 3’’
+
-
5.6
the writing
“Au to”
will appear, the burner works at MAX and appears on the display
P1
press the
‘’D‘’
key to display the value (eg 31).
Read the pressure value MAX on the pressure gauge and compare it with the value in the table NOZZLES
PRESSURE Chap. 4.2. (ed. 14.1). Considering the example shown in the figure, having to calibrate the
valve to 14.1 mbar it can be concluded that it is a VALUE TOO LOW therefore:
Press the
“D”
button for about 3“;
“tA”
menu will appear again.
Activate the calibration function by pressing the
“D”
button for about 3“;
service
x 3’’
Pressure MAX P1
service
4.4.2 - ADJUSTMENT - TARATURA Auto