General
9
0.6.5.
Scope of compliance
Use equipment only in the zone for which it is appropriate and suitably rated.
0.6.6.
Marking
An example of ATEX equipment marking is shown below. The classification of the pump will be engraved
on the nameplate (Fig 1).
Fig 1 Example ATEX Nameplate
Special attention must be paid to the marking on the ATEX nameplate.
It is essential to comply with the instruction prohibiting dismantling of the equipment in a flammable
atmosphere where applicable.
0.6.7.
Avoiding excessive surface temperatures
WARNING
- ENSURE THE EQUIPMENT TEMPERATURE CLASS IS SUITABLE FOR THE
HAZARD ZONE
0.6.8.
Pump media temperature
Pumps have a temperature class as stated on the nameplate. These are based on a maximum ambient of
40 ºC (104 ºF). Refer to Flotronic Pumps if higher ambient temperatures are to be considered.
Where there is any risk of the pump being run for prolonged periods against a closed or partially closed
valve generating high media and casing external surface temperatures, it recommended that users fit an
external surface temperature protection device.